BPC-157 Certificate of Analysis (COA) Explained
A certificate of analysis (COA) is the test report for one lot of a compound. This guide walks through the current Zerilyx BPC-157 10mg certificate field by field, using only the values published on it. The certificate itself is on the BPC-157 certificate page.
The fields on the current BPC-157 certificate
| Field | Value on the certificate |
|---|---|
| Product | BPC-157 |
| Size | 10mg |
| Lot | Z-BPC-00144 |
| Certificate number | COA-2026-ZSYI6J |
| Test date | 2026-10-29 |
| Laboratory | ILS Laboratories |
| Purity | 99.71% |
| Purity method | HPLC |
| Net peptide content | 10.24 mg (report only) |
| Tests listed | Peptide Purity (HPLC), Net Peptide Content, Identity (HPLC-RTM), Fentanyl Screen |
Lot and certificate number
The lot, Z-BPC-00144, identifies the production batch the tested sample came from. It is the first thing to check: the lot on the certificate should match the lot printed on the vial label exactly. The certificate number, COA-2026-ZSYI6J, identifies the report itself. See Peptide Lot Traceability for why the match matters.
Test date and laboratory
The sample was tested on 2026-10-29 by ILS Laboratories. Naming the lab means the result can be traced to the organization that produced it, rather than to the seller.
HPLC purity: 99.71%
High-performance liquid chromatography (HPLC) separates the components of a sample, and a UV detector measures each one as it elutes. Purity is the area of the main peak as a percentage of all UV-absorbing peaks. A result of 99.71% means 99.71% of the UV-absorbing material detected was the target peptide, and the remainder was other material such as related peptides from synthesis.
HPLC purity does not measure how much of the powder is peptide. Counter-ions and residual moisture do not absorb in the same way, so they are reported separately.
Identity: HPLC retention-time match
The certificate lists identity by HPLC-RTM, a retention-time match. The time the main peak takes to pass through the column is compared with the time for a reference of the expected compound under the same conditions. Agreement supports that the main peak is the expected compound.
This is a different identity method from mass spectrometry, which measures molecular mass directly. The current certificate does not list a mass spectrometry result, so there are no expected and observed molecular mass values to compare on this report.
Net peptide content: 10.24 mg
A lyophilized peptide powder contains the peptide plus counter-ions and some residual moisture. Net peptide content reports the amount of peptide itself. On this certificate it is 10.24 mg for the 10mg vial, marked "report only," which means the value is reported for information rather than tested against a pass or fail limit. See Peptide Purity Testing for how purity and net peptide content relate.
Fentanyl screen
The certificate also lists a fentanyl screen. It is a contaminant screen, separate from purity and identity, and reports on that one substance only.
Reading the chromatogram
The purity figure comes from a chromatogram: a plot of detector response against time. The target peptide appears as one large peak, and any other UV-absorbing material appears as smaller peaks before or after it. The lab integrates the area under each peak and divides the main peak's area by the total. When you look at the chromatogram image on a certificate, check that there is one clearly dominant peak, that the baseline is reasonably flat and that the reported percentage agrees with what the plot shows. A purity number printed with no chromatogram behind it is harder to check.
What this certificate does not cover
A certificate reports only the tests it lists. This one lists four. It does not report sterility or endotoxin testing, and it describes only lot Z-BPC-00144. A different lot needs its own certificate.
Checking your vial
Compare the lot on your vial with the lot on the BPC-157 certificate page. For a general guide to every field on a peptide certificate, see How to Read a Peptide COA. If your lot is not listed, email help@zerilyx.com with the lot number from your vial.
For Research Use Only. Not for human or veterinary use. Not for diagnostic or therapeutic purposes.